Magnetic Encoder Ring Selection Guide: Pole pitch, Pole pairs, Air Gap & Material

Select a magnetic encoder ring by first matching the encoder IC’s magnetic-target requirements: pole pitch, pole-pair count, track geometry and magnetic field at the sensing position. Then choose the ring dimensions, air gap, carrier and material around the installation and working environment.

If you have not selected a chip, start with OTV’s magnetic encoder IC selection page. If the chip is already selected, the two examples below show how to turn its datasheet into a ring specification: iC-MU150 for absolute rotary feedback and iC-MHL200 for incremental rotary feedback.

Start with the chip datasheet, then design the magnetic ring

The IC sets the magnetic pattern that the ring must deliver. The application sets the installation envelope and environmental requirements. Work through both in that order.

Target requirementiC-MU150: absolute rotaryiC-MHL200: incremental rotary
Single-pole width, p1.50 mm on the master track2.00 mm on the measuring track
Full N/S period, λ = 2p3.00 mm4.00 mm
Pole pairs and tracksMaster/Nonius: 16/15, 32/31 or 64/63; two tracksOne periodic measuring track; select a suitable integer pole-pair count for the scan circumference and system
Operating magnetic field, Hext15–100 kA/m at the chip surface20–100 kA/m at the chip surface
Dimension-setting constraintMaster and Nonius scan diameters plus 3.6 mm scan-track center spacingMaintain 2.00 mm single-pole width; evaluate the chosen ring’s curvature and field

Sources: iC-MU Series Rev. B1, pp. 11 and 17; iC-MU150 Rev. E1, pp. 10 and 15; iC-MHL200 Rev. E1, pp. 8 and 14. Values apply under each document’s stated conditions. Hext is the operating field at the specified chip location, rather than the magnet material’s remanence Br.

Define “pole pitch” on the drawing. Here, p means the width of one N or S pole. One complete N/S period is 2p. A ring with 64 alternating poles therefore has 32 pole pairs.

Absolute rotary example: selecting a magnetic ring for iC-MU150

iC-MU150 requires a coordinated two-track Nonius target. Keep the master single-pole width at 1.50 mm, choose a supported pole-pair combination, and preserve the scan-track geometry. The mechanical carrier can then be designed around those magnetic requirements.

1. Confirm the master-track pole pitch: 1.50 mm

The Hall sensors are manufactured at fixed positions on the silicon. Their spacing defines the spatial pattern the sensor array is designed to sample. For iC-MU150, the master single-pole width is 1.50 mm and the N/S period is 3.00 mm. Changing software settings does not change that physical Hall-array spacing.

The inner Nonius track has its own geometry. In a rotary target, it follows a smaller circumference and has one fewer pole pair. Do not apply the linear-scale Nonius pitch formula to the rotary ring.

2. Confirm the pole pairs and scan diameters

Master / Nonius pole pairsMaster scan diameterNonius scan diameterMaster single-pole widthNonius single-pole width
16 / 1515.28 mm8.08 mm1.50 mm0.85 mm
32 / 3130.56 mm23.36 mm1.50 mm1.18 mm
64 / 6361.11 mm53.92 mm1.50 mm1.34 mm

Rotary dimensions: iC-MU150 Rev. E1, Table 1, p. 15. The 3.6 mm track-center separation is also stated in iC-MU Series Rev. B1, p. 17. These are magnetic scan dimensions, not ring bore or carrier OD.

iC-MU150 dual-track absolute encoder ring example with 32 master pole pairs, 31 Nonius pole pairs, 30.56 mm and 23.36 mm scan diameters and 3.6 mm track spacing
A typical 32/31-pair rotary target: outer master track and inner Nonius track. The IC reads both to resolve absolute position within one revolution.
Open the track diagram at full size ↗

3. Confirm the field at the chip: 15–100 kA/m

The field must meet the chip’s requirements at the intended sensing position throughout rotation and over the installation gap and temperature range. Checking the bulk magnet grade or its surface-field value at another location does not establish this.

If your magnetic supplier reports B in mT, agree the measurement position and units before comparing results with Hext in kA/m. Also include the package geometry: the datasheet lists a 400 µm sensor-to-package-surface distance.

4. Customize the bore, carrier and mounting features around the tracks

The required magnetic scan zones must remain at the correct radii. Outside those zones, the physical ring and carrier can be adapted to the application. A smaller inner bore, a larger outer carrier, locating holes or tapped mounting holes can be considered without redefining the required magnetic code.

Place machined locating and threaded features in a suitable metal carrier or hub. Review track width and edge margins, nearby ferromagnetic material, adhesive, stress and runout when changing the structure. The final assembly still needs field and position-error validation.

OTV custom magnetic ring and standard ring designs, showing magnetic viewing-film patterns and a plain standard ring face
Custom and standard magnetic-target constructions. The custom carrier provides a different bore and mounting structure while the magnetic scan zones are designed to match the selected IC.
Open the product comparison at full size ↗

Compare OTV’s standard absolute magnetic rings and encoder discs, or discuss a custom magnetic ring and carrier.

iC-MUE: more flexibility for absolute magnetic ring design

iC-MUE gives designers more freedom in selecting supported magnetic scale sizes and Nonius combinations. Its decimal Nonius engine broadens the design space compared with the legacy iC-MU150 example. It remains necessary to match the target to iC-MUE’s own magnetic-input and geometry requirements.

The manufacturer’s Rev. 1 factsheet describes dual-track scales with 8–64 pole pairs, magnetic scale sizes ≥20 mm, and Hall sensors optimized for a 2.00 mm master single-pole width. It also includes automatic adjustment, eccentricity compensation and a correction LUT. The scale-size statement is not a minimum bore specification.

Use this flexibility when an application’s preferred ring diameter does not fit a legacy target size. Review the allowed configuration and actual target design rather than assuming an iC-MU150 ring can be transferred unchanged. Read more about iC-MUE and custom magnetic rings for robot joints and magnetic-ring compatibility between encoder ICs.

iC-MUE axial magnetic disc scanning diameter illustration
iC-MUE axial disc configurations with different scanning diameters. Confirm the selected magnetic target against the IC requirements.
View the diameter illustration at full size

Source: iC-MUE Rev. 1 preliminary factsheet, pp. 1–2; the final component and target selection should follow the applicable manufacturer release.

Incremental rotary example: selecting a ring for iC-MHL200

iC-MHL200 uses one periodic magnetic measuring track with a 2.00 mm single-pole width. Removing the paired Nonius track gives more freedom in selecting the ring’s scan circumference and mechanical form. The local pole width and magnetic field still have to match the sensor.

ParameterDatasheet requirement or design action
Pole pitch2.00 mm for one N or S pole; 4.00 mm for one full N/S period.
Pole-pair countNo MU150-style 16/15, 32/31 or 64/63 Nonius constraint. Select a suitable integer count around the chosen scan circumference.
Magnetic fieldHext = 20–100 kA/m at the chip surface under the stated datasheet conditions.
Sensor locationThe TSSOP package lists a 0.4 mm chip-surface-to-package-top distance. Account for this when defining the gap.
Ring size and operationValidate curvature, readhead placement, gap, signal quality and magnetic frequency at the intended rotational speed.

Source: iC-MHL200 Rev. E1, Electrical Characteristics p. 8 and Basic Operation p. 14. The pole-pair choice is a ring/system design decision; the document does not provide an unrestricted set of approved ring diameters.

Choose pole pairs and scan diameter together

For a uniformly spaced circular track, Dscan = 2 × P × p / π, where P is pole pairs and p is single-pole width. With p = 2.00 mm and a chosen P = 32, the calculated scan diameter is 40.74 mm. Evaluate that geometry with the actual readhead rather than treating the calculated diameter as a manufacturer-approved minimum.

Single-track incremental magnetic ring for iC-MHL200 showing a 2.00 mm single-pole width, 4.00 mm N/S period and a calculated 40.74 mm scan diameter for 32 pole pairs
A single-track incremental target has no second-track alignment constraint. Keep the specified pole width while selecting the pole count, carrier and mounting arrangement.
Open the single-track diagram at full size ↗

A single periodic track provides repeating position information; full-revolution reference recovery depends on the system’s referencing method. Increasing pole count or interpolation does not by itself establish measurement accuracy.

Choose the air gap from the field requirement and installation tolerances

Define the air gap

The usable air gap depends on the selected IC and magnetic target combination. Set the installation so the required field and signal quality are maintained at the minimum and maximum working distances, including assembly variation, runout and temperature.

In the axial off-axis installation illustrated here, g is measured from the bottom surface of the IC package to the magnetic target surface. It is a mechanical installation distance. The magnetic-field limits quoted earlier still apply at the manufacturer’s specified chip/sensor location; account for the sensor depth separately when checking those limits.

Calculate the air gap when protective layers are present

Include any additional coating on the IC bottom and any cover over the magnetic target. At the same permitted IC-bottom-to-target distance, these layers reduce the air clearance remaining between the coated surfaces.

Free air clearance = g − added IC coating thickness − added target cover thickness.

For an illustrative g of 0.60 mm, a 0.05 mm IC coating and a 0.10 mm target cover leave 0.45 mm of free air clearance. Use the actual target/readhead limits when setting g.

Axial off-axis magnetic encoder ring and IC layout with g measured from the IC bottom surface to the magnetic target surface, including protective coatings
g starts at the IC bottom surface and ends at the magnetic target surface. Protective layers consume part of that distance; the remaining space is the free air clearance.
View the axial installation diagram at full size

If the free mechanical clearance is kept unchanged while adding a cover, the IC-bottom-to-target distance increases. Recheck the field and signal quality at the IC across the resulting installation range.

For a benign, non-contact installation, OTV generally recommends avoiding an additional protective layer on the magnetic target unless the application requires it. Where contamination, corrosion or handling calls for protection, qualify the complete covered target and readhead arrangement.

Choose the capable magnetic material: rubber magnetic, injection plastic magnetic or hard ferrite magnetic

For many multipole ring designs, a rubber-bonded magnetic layer on a carrier is a practical starting point. It is convenient to shape and integrate, and its compliance can help accommodate differential thermal expansion. Confirm the magnetic layer, adhesive and carrier together through thermal cycling.

Rubber-bonded ferrite often provides a lower field than rare-earth-filled alternatives, but it can still satisfy the IC’s input window. Compare actual grades and constructions: rubber-bonded and injection-bonded describe binder/process choices, while ferrite describes a magnetic material.

ConstructionWhy consider it?What to check?
Rubber-bonded magnetic layerFlexible layer; convenient shaping and integration with a custom carrier.Field at the working gap, binder grade, adhesive, fluids, temperature and thermal cycling.
Injection-bonded magnetMolded geometry and binder/compound options for the required environment.Ferrite or rare-earth powder, polymer grade, tooling, shrinkage and feature tolerances. Thermal capability is grade-specific.
hard ferrite magnetRigid ceramic magnetic target; a candidate for suitably designed higher-temperature assemblies.Brittleness, grinding, mounting stress, minimum practical wall/section thickness and carrier attachment.

What if the working temperature exceeds 120°C?

For a design requiring operation above 120°C, review qualified high-temperature injection-bonded compounds and hard ferrite magnet early in the selection process. Also check the adhesive and carrier. Use the actual material grade and test conditions to set the rating; 120°C is a design-review trigger here, rather than a universal maximum for every rubber magnet.

What if the magnetic layer needs to be about 1 mm thick?

Bonded constructions are worth considering early for thin targets. A hard ferrite magnet part can be difficult to manufacture, handle and mount in thin sections because it is brittle. For a thickness around 1 mm, have the supplier approve the complete geometry and production process before finalizing the drawing; avoid treating one thickness as a universal material limit.

For a rigid ferrite route, see OTV’s hard ferrite magnetic rings. Background on binder and magnetic-material trade-offs is available in Arnold Magnetic Technologies’ bonded/sintered magnet comparison.

Use OTV’s ring designer, then discuss the chip, magnetic ring or module

The OTV magnetic encoder ring designer helps you explore target geometry and communicate your application. Use the selected IC’s requirements as the starting point, then share the design for a magnetic and mechanical review.

OTV magnetic encoder rings and carrier configurations

Matched magnetic rings

Review the magnetic pattern, field, bore, carrier and mounting features around your installation.

Discuss a custom target →
OTV-OME absolute off-axis rotary encoder ring and readhead module

Encoder modules

Compare an existing readhead-and-ring solution when it fits the mechanical and control architecture.

Explore OTV-OME modules →

Share your magnetic encoder application with OTV Sensing

Send the IC or readhead model, a drawing or sketch, available bore and outer envelope, expected gap, speed and working environment. If some inputs are still open, tell us what the application needs to achieve.

Discuss your chip + ring requirementsthomas@otvsensing.com ↗

Magnetic encoder ring selection: quick answers

Can I change the iC-MU150 master pole pitch?

The master single-pole width is 1.50 mm, defined by the fixed Hall-array spacing. Keep that magnetic geometry and customize the mechanical structure around the required scan zones.

Can I use a smaller bore or a larger ring OD?

Yes, a custom structure may provide a smaller bore or larger outer carrier while preserving the required scan-track geometry, clearances and field. Have the complete design reviewed before manufacturing.

Is an iC-MHL200 ring unrestricted because it has one track?

No. A single track removes the Nonius-track constraint, but the 2.00 mm pole width, field requirement, curvature, operating gap and speed still need to be satisfied.

Should I choose the strongest magnetic material?

Choose a material and construction that produce the required field at the chip across the operating conditions. Additional field strength does not automatically improve position accuracy.

Shopping Cart