OTV Sensing · IC + matched magnetic scale

Linear Magnetic Encoder IC Selection

Select a linear encoder IC and its magnetic scale as one sensing system. OTV Sensing supplies encoder chips and custom magnetic scales, with support from sample quantities through matched targets and complete encoder modules.

Find an IC + scale starting point

Set the position architecture, required stroke, output step and controller interface. Candidates needing extra tracks, interpolation or scale validation remain clearly flagged for engineering review.

14 devices listed. Enable JavaScript for live filtering.

Output step is digital resolution, not guaranteed accuracy. Coded length needs end margins; filtered serial resolution may add latency. Unknown specifications remain review items.

Absolute stroke, incremental travel or battery-retained position?

Coded absolute position

A matched multi-track scale gives a unique position over a finite coded length. The iC-MU family uses a master track and a Nonius track; a longer stroke can require another architecture.

Incremental / periodic phase

Repeated poles support long scales, but a controller must establish and retain the reference. An absolute SSI value within one period is not an absolute coordinate over the entire machine stroke.

Battery-retained counting

iC-PVS buffers period counting with a backup supply. A valid datum, retained count and defined recovery after tracking or battery loss are part of the system design.

Linear magnetic encoder IC comparison

Select candidate chips to carry them into the joint enquiry. Scroll the table horizontally for scale, output and installation details. Every row links to the supporting documentation below.

IC / add to RFQPosition & measuring rangeResolution & accuracyMatched magnetic scaleOutputs & speedAir gap & magnetic environment
iC-HausSelect requirements above[S5] [S6]Coded Nonius absolute; configurable incremental outputs

40.96 / 81.92 / 163.84 mm coded lengths; usable stroke needs end margins. Three-track/second-IC extensions require review.

0.625 µm nominal real-time; ~0.156 µm serial with14-bit filtering. ABZ increment depends on range/FlexCount.
Accuracy conditions

Converter:2 LSB of12-bit sine period with ideal inputs; installed linear accuracy must be established for target/mounting/calibration.

Master1.28 mm single poles /2.56 mm N+S period; matched Nonius16/15,32/31 or64/63;3.6 mm sensor track spacing.SSI, BiSS-C, SPI, ABZ, STEP/DIR, Analog Sin/Cos

17 m/s per current B1, hardwareX1+; filter/output configuration limits still apply.

Target/field dependent; verify matched scale and package stack.400 µm sensor depth is not air gap.
Field & stray-field limits

15–100 kA/m target field at die; operating field is not stray-field immunity.

Differential sensing; no guaranteed external-field immunity limit in mT supplied.

iC-HausSelect requirements above[S5] [S7]Coded Nonius absolute; configurable incremental outputs

48 /96 /192 mm coded lengths; usable stroke needs end margins. Three-track/second-IC extensions require review.

~0.732 µm nominal real-time; ~0.183 µm serial with14-bit filtering. ABZ32-period example:0.3662 µm at262144 edges.
Accuracy conditions

Converter:2 LSB of12-bit sine period with ideal inputs; installed linear accuracy must be established for target/mounting/calibration.

Master1.50 mm single poles /3.00 mm N+S period; matched Nonius16/15,32/31 or64/63;3.6 mm sensor track spacing.SSI, BiSS-C, SPI, ABZ, STEP/DIR, Analog Sin/Cos

20 m/s; filter/output configuration limits apply.

Target/field dependent; verify matched scale and package stack.400 µm sensor depth is not air gap.
Field & stray-field limits

15–100 kA/m target field at die; operating field is not stray-field immunity.

Differential sensing; no guaranteed external-field immunity limit in mT supplied.

iC-HausSelect requirements above[S5] [S8]Coded Nonius absolute; configurable incremental outputs

64 /128 /256 mm coded lengths; usable stroke needs end margins. Three-track/second-IC extensions require review.

~0.977 µm nominal real-time; ~0.244 µm serial with14-bit filtering. ABZ32-period example:0.4883 µm at262144 edges.
Accuracy conditions

Converter:2 LSB of12-bit sine period with ideal inputs; installed linear accuracy must be established for target/mounting/calibration.

Master2.00 mm single poles /4.00 mm N+S period; matched Nonius16/15,32/31 or64/63;4.0 mm sensor track spacing.SSI, BiSS-C, SPI, ABZ, STEP/DIR, Analog Sin/Cos

20 m/s; filter/output configuration limits apply.

Target/field dependent; verify matched scale and package stack.400 µm sensor depth is not air gap.
Field & stray-field limits

15–100 kA/m target field at die; operating field is not stray-field immunity.

Differential sensing; no guaranteed external-field immunity limit in mT supplied.

iC-HausSelect requirements above[S9]Battery-retained period counter; initial datum required

System/scale dependent; up to56-bit battery-buffered period counter. Initial datum and valid continuous tracking/backup required; not a unique full-stroke coded scale.

Native6-bit /64 increments per magnetic period: calculated31.25–78.125 µm for1–2.5 mm poles; finer resolution needs external interpolation.
Accuracy conditions

No numeric installed linear accuracy in preliminary factsheet; downstream interpolation, scale and mounting require validation.

Periodic scale with1.0–2.5 mm single poles; differential Hall scanning; maintain tracking and backup for retained absolute position.SSI, BiSS-C, SPI, ABZ, Analog Sin/Cos, Parallel

Up to75 m/s specifically at1.5 mm poles;25 kHz max magnetic input; other pitches/output settings need review.

Not specified in factsheet; matched scale/field/gap validation required.
Field & stray-field limits

10–100 kA/m target field. Battery-buffered counting requires valid backup and tracking.

Differential scanning, qualitative high immunity; no quantified guaranteed mT limit in factsheet.

ams / ams OSRAMSelect requirements above[S1]Period-local absolute phase + incremental

active scale length minus 2 mm Hall array; extended position needs counts/reference. Absolute phase repeats every 2 mm.

0.488 µm SSI/PWM phase; 1.953 µm per A/B transition.
Accuracy conditions

INL ±5.6 µm ideal magnet at25°C, best-line fit; ±10 µm at−30…+70°C; not installed system accuracy

1 mm single-pole width / 2 mm full N+S period; periodic index is not a unique full-scale reference.SSI, PWM, ABZ

Up to 0.65 m/s for incremental tracking; serial/PWM dynamics need separate review.

0.3 mm typical package-to-magnet table; application typical0.3–0.6 mm, field/AGC dependent
Field & stray-field limits

10–40 mT target-field amplitude at the specified sensor datum.

Constant magnetic offset ±5 mT; constant offset only; variation including offset gradient ±2%.

ams / ams OSRAMSelect requirements above[S2] [S3]Incremental quadrature; reference-dependent

scale length and controller counts; requires reference/homing, no globally absolute stroke stated Lifecycle: confirm exact ordering suffix; official discontinuation notice covers AS5304A and AS5306A/B.

25 µm per quadrature transition (160 transitions per magnetic period).
Accuracy conditions

table INL2.5 LSB ideal input, (ErrMax−ErrMin)/2; calculated62.5 µm; later ideal-magnet prose says <1 LSB, inconsistency retained

2 mm single-pole width / 4 mm full N+S period; periodic index is not a unique full-scale reference.ABZ

Up to 20 m/s, configuration dependent.

≤0.8 mm magnet-to-package surface recommendation, magnet strength dependent; die-surface equivalent≤1.0 mm
Field & stray-field limits

10–60 mT target-field amplitude at the specified sensor datum.

Constant magnetic offset ±0.5 mT; table magnetic offset value, not a universal stray-gradient immunity rating.

ams / ams OSRAMSelect requirements above[S2] [S3]Incremental quadrature; reference-dependent

scale length and controller counts; requires reference/homing, no globally absolute stroke stated Lifecycle: confirm exact ordering suffix; official discontinuation notice covers AS5304A and AS5306A/B.

15 µm per quadrature transition (160 transitions per magnetic period).
Accuracy conditions

table INL2.5 LSB ideal input, (ErrMax−ErrMin)/2; calculated37.5 µm; later ideal-magnet prose says <1 LSB, inconsistency retained

1.2 mm single-pole width / 2.4 mm full N+S period; periodic index is not a unique full-scale reference.ABZ

Up to 12 m/s, configuration dependent.

≤0.4 mm magnet-to-package surface recommendation, magnet strength dependent; die-surface equivalent≤0.6 mm
Field & stray-field limits

10–60 mT target-field amplitude at the specified sensor datum.

Constant magnetic offset ±0.5 mT; table magnetic offset value, not a universal stray-gradient immunity rating.

iC-HausSelect requirements above[S10]Incremental / period-local phase

Scale length, end margins, referencing and controller counting determine usable travel; no intrinsic long-stroke limit is specified.

0.488 µm nominal output step; 4096 steps per 2 mm magnetic period.
Accuracy conditions

Converter phase accuracy ±0.35° at Vpp=4 V, adjusted; installed linear accuracy not specified

Repetitive N/S linear scale, 1.00 mm single-pole width; unique reference/counter required for longer travel Full N+S period 2 mm.ABZ, BiSS-C, SSI, UVW

Up to 4 m/s. 4096 steps per period, minimum transition distance125ns; 2kHz magnetic frequency

No universal air-gap range specified; validate field/signal amplitude for matched scale
Field & stray-field limits

20–100 kA/m at chip surface

No quantified immunity guarantee found

iC-HausSelect requirements above[S11]Incremental / period-local phase

Scale length, end margins, referencing and controller counting determine usable travel; no intrinsic long-stroke limit is specified.

0.977 µm nominal output step; 4096 steps per 4 mm magnetic period.
Accuracy conditions

Converter phase accuracy ±0.35° at Vpp=4 V, adjusted; installed linear accuracy not specified

Repetitive N/S linear scale, 2.00 mm single-pole width; unique reference/counter required for longer travel Full N+S period 4 mm.ABZ, BiSS-C, SSI, UVW

Up to 8 m/s. 4096 steps per period, minimum transition distance125ns; 2kHz magnetic frequency

No universal air-gap range specified; 0.4 mm die depth is package geometry, not air gap
Field & stray-field limits

20–100 kA/m at chip surface

No quantified immunity guarantee; stray fields are a system influence

iC-HausSelect requirements above[S12]Incremental / period-local phase

Scale length, end margins, referencing and controller counting determine usable travel; no intrinsic long-stroke limit is specified.

20.000 µm nominal output step; 8-bit over 5.12 mm full period.
Accuracy conditions

Installed linear accuracy not specified; relative edge error ±20% is a separate datasheet quantity

Nominal 2.56 mm single-pole width; smaller pitch via skewed mounting requires validation Full N+S period 5.12 mm.ABZ, Analog Sin/Cos, Counter pulses

Up to 5 m/s.

No universal gap specified
Field & stray-field limits

20–100 kA/m at chip surface

Differential homogeneous-field rejection; no quantified mT limit

iC-HausSelect requirements above[S13]Analog incremental front end; external interpolation required

Scale length, end margins, referencing and controller counting determine usable travel; no intrinsic long-stroke limit is specified.

External interpolator determines digital step
Accuracy conditions

±1° electrical phase without offset voltage, sensor bottom-edge gap0.5mm; not installed system accuracy

2 mm single-pole width, 4 mm N+S period; AMR outputs one electrical cycle per pole width AMR electrical period 2 mm; distinguish it from the N+S period.Analog Sin/Cos

Analog chain/interpolator dependent; no max linear speed specified

Amplitude variation ±5% characterized at0–1.5mm; accuracy characterized at0.5mm. Not a universal allowed-gap rating
Field & stray-field limits

|Hext| >25 kA/m at sensor bottom edge

Qualitative homogeneous-field immunity; no numerical stray-field rating

iC-HausSelect requirements above[S14]Analog incremental front end; external interpolation required

Scale length, end margins, referencing and controller counting determine usable travel; no intrinsic long-stroke limit is specified.

External interpolator determines digital step
Accuracy conditions

±1° electrical phase without offset voltage, sensor bottom-edge gap1mm; not installed system accuracy

5 mm single-pole width, 10 mm N+S period; AMR outputs one electrical cycle per pole width AMR electrical period 5 mm; distinguish it from the N+S period.Analog Sin/Cos

Analog chain/interpolator dependent; no max linear speed specified

Amplitude variation ±5% characterized at0–2.5mm; accuracy characterized at1mm. Not a universal allowed-gap rating
Field & stray-field limits

|Hext| >25 kA/m at sensor bottom edge

Qualitative homogeneous-field immunity; no numerical stray-field rating

MultiDimension Technology / MDTSelect requirements above[S15] [S16]Analog incremental front end; external interpolation required

Scale length, end margins, referencing and controller counting determine usable travel; no intrinsic long-stroke limit is specified.

External interpolator determines digital step
Accuracy conditions

Guaranteed installed positional accuracy not specified Manufacturer announcement gives typical ±1 µm repeatability, with incomplete test conditions; it is not an accuracy guarantee.

0.4 mm single-pole width; manufacturer MLT1080/MLT2080 accessories have customizable lengths Full N+S period 0.8 mm.Analog Sin/Cos

No numeric linear-speed limit established here.

0.15 mm test gap for output amplitude at1V,25°C; permissible gap range not specified
Field & stray-field limits

Amplitude-vs-field characteristic only; no validated universal range entered

Manufacturer describes differential gradiometric rejection; no numerical mT rating

ams / ams OSRAMSelect requirements above[S4] [S3]Legacy two-pole-magnet displacement sensor

Historical short-stroke concept, not a periodic magnetic tape reader. Current numerical travel not verified for selection.

Current verified output increment unavailable; note’s blanket 14-bit / ±25 mm claim is not used.
Accuracy conditions

Not verified for a current supplied configuration.

Historical two-pole magnet target; not a standard multipole linear scale.SPI, PWM

Not verified for current selection.

The note’s approximately 10 mm gap was not verified.
Field & stray-field limits

Target field and installation need document review.

No current quantified immunity verified.

AS5410 is a historical, discontinued reference. Confirm exact AS5304 / AS5306 ordering variants before a new design. Analog front ends require external interpolation; manufacturer converter tests and typical repeatability are not full-scale accuracy guarantees.

Match pole width, track code and air gap before choosing a scale

Single-pole width, magnetic period and encoder architectureA north and a south pole form a full magnetic period. Hall sensing and AMR electrical periods differ. Repeated single tracks need counting; a matched Nonius pair provides a finite coded absolute range.Design the scale for the sensor arraySingle-pole width pFull N+S magnetic period = 2pNSNSNSNSHall magnetic cycle: usually N+S (2p)SM2L / SM5L AMR electrical cycle: pRepeated single track → periodic phase + counting/referenceMatched Nonius tracks → finite coded absolute lengthSchematic only. Confirm pole definition, track relationship and gap with the selected IC datasheet.Encoder ICTrack geometry + sensor spacingField at the die + mounting gapOutput interpolation + calibration
Original OTV explanatory schematic. The magnetic N+S period and the electrical signal period must be interpreted for the selected sensing technology.

Same length does not mean the same magnetic code

The sensor-array spacing sets the required magnetic pole geometry. A 1.28 mm master single pole corresponds to a 2.56 mm N+S period for iC-MU128. The Nonius track uses a different matched pole spacing; copying the master pattern onto both tracks cannot reproduce that code.

AMR sensors such as iC-SM2L and iC-SM5L have an electrical cycle per single-pole width. Specify whether a drawing means a single pole, an N+S pair or an electrical cycle.

Validate the installation as a system

Define the gap datum, tolerance, tilt and lateral offset. Then verify signal amplitude, interpolation error, scale pitch error, temperature drift and stray-field gradients. A target operating field specification does not establish immunity to external motor fields.

Magnetic encoder scale strip with backing and magnetic viewing film showing the repeated pole pattern
Magnetic scale and viewing-film example from OTV’s product library. The image does not specify a chip-compatible pole pitch or an installed accuracy.

OTV supplies encoder ICs, custom magnetic scales and complete modules

Encoder IC supply

Request chips in the quantity your project needs, including small sample batches, subject to availability. We also support PCBA prototyping using your Gerber files, BOM and assembly information.

Explore encoder IC supply →

Matched magnetic scales

Discuss pole width, single or multi-track coding, usable stroke, end margins, backing, adhesive, width and thickness together with the selected sensor and installation gap.

Explore magnetic scales and encoder tape →

For rotary projects, use the off-axis rotary encoder IC selector and matched magnetic rings and encoder disks.

Request a joint quotation: encoder IC + custom magnetic scale

Choose chips in the table, or leave the choice to OTV. Add the mechanical constraints below; your filter settings and selected chips are included automatically in the enquiry form.

Review the generated requirements before sending. A shortlist is a design starting point, not a compatibility or supply guarantee.

Generated from your selected chips, filters and scale requirements. Review before sending; if JavaScript is unavailable, enter these requirements manually.
Privacy policy: https://otvsensing.com/privacy-policy/

Engineering questions before a linear encoder design is frozen

Can SSI or BiSS alone prove that a chip is full-stroke absolute?

No. AS5311 and MHL devices report phase within a repeating magnetic period. A full machine coordinate also needs a unique coded scale or a valid count and reference architecture. The interface name does not define the measuring range.

Does a smaller output step guarantee better positioning accuracy?

No. Quantization, signal interpolation, magnetic pitch error and mounting error are different contributions. Compare specifications under their stated conditions, then verify the matched scale and readhead across the usable stroke.

Can an incremental scale have any travel length?

The repeated pattern is not limited to a single magnetic period, but scale manufacturing length, mechanical mounting, controller counting capacity, speed and reference recovery still constrain the usable system.

Can I request samples without a final chip selection?

Yes. Send the required stroke, resolution, output interface and mounting envelope. OTV can review IC and scale candidates together; confirm availability and a validation plan before design release.

Datasheet sources and specification conditions

Reviewed 25 November 2026. Numerical output steps calculated from documented period and interpolation are identified above. Unpublished installation limits remain unverified rather than assumed.

  1. [S1] AS5311 datasheet, Rev 1.13. pp. 7–8, 12, 19–20: period-local SSI/PWM, AB step, ideal-magnet INL and field conditions.
  2. [S2] AS5304 / AS5306 datasheet, v3-00. pp. 7, 9–11, 13, 15–16, 22. INL uses the conservative 2.5 LSB electrical-table value; prose elsewhere differs.
  3. [S3] ams official product discontinuation notice, 10 Aug 2021. AS5410-ZTSM, AS5304A and AS5306A/B ordering variants. Availability must be confirmed.
  4. [S4] AS5410 preliminary Rev 1.5, historical manufacturer-authored PDF. Distributor-hosted historical reference, not a current production recommendation; stroke depends on the specific two-pole magnet.
  5. [S5] iC-MU128 / current iC-MU Series B1 documentation. B1 (2025), hardware X1+: p. 11 speed, p. 49 serial filtered increments. Nominal real-time steps are calculated as N+S period / 4096.
  6. [S6] iC-Haus MU family linear-range factsheet, Rev 6. Basic two-track coded lengths and advanced three-track / second-IC extensions are different architectures.
  7. [S7] iC-MU150 documentation. Local E1: pp. 10–11, 15, 41–42, 50; scale geometry and serial interpolation conditions.
  8. [S8] iC-MU200 documentation. Local B2: pp. 8–9, 14, 40–41, 48; scale geometry and serial interpolation conditions.
  9. [S9] iC-PVS preliminary factsheet, Rev 2. pp. 1–2: battery-buffered counting and native 6-bit phase. Step = N+S period / 64.
  10. [S10] iC-MHL100 datasheet, A1 preliminary. pp. 1–2, 7–9, 22, 26: converter, speed and BiSS framing. UVW commutation is not the full-resolution position output.
  11. [S11] iC-MHL200 datasheet, E1. pp. 1–2, 7–9, 22, 26: 4 mm magnetic period, converter accuracy and serial output.
  12. [S12] iC-ML datasheet, A3. pp. 1–2, 4–5, 7: 2.56 mm pole width, 8-bit interpolation and output options.
  13. [S13] iC-SM2L datasheet, C1. pp. 1–2, 5: AMR electrical period, specified phase-error test gap and amplitude-characterization range.
  14. [S14] iC-SM5L datasheet, B2. pp. 1–2, 5: AMR electrical period and gap-dependent amplitude; external interpolation required.
  15. [S15] TMR4101 datasheet: local CN v1.2.4 / online EN v1.2.3. Analog output, 0.4 mm single poles. 0.15 mm is an amplitude-test gap, not a guaranteed installation range.
  16. [S16] MultiDimension Technology TMR4101 manufacturer announcement. Typical ±1 µm repeatability is not a guaranteed installed accuracy specification.
Shopping Cart