OTV Sensing · IC + matched magnetic scale
Linear Magnetic Encoder IC Selection
Select a linear encoder IC and its magnetic scale as one sensing system. OTV Sensing supplies encoder chips and custom magnetic scales, with support from sample quantities through matched targets and complete encoder modules.
Find an IC + scale starting point
Set the position architecture, required stroke, output step and controller interface. Candidates needing extra tracks, interpolation or scale validation remain clearly flagged for engineering review.
14 devices listed. Enable JavaScript for live filtering.
Output step is digital resolution, not guaranteed accuracy. Coded length needs end margins; filtered serial resolution may add latency. Unknown specifications remain review items.
Absolute stroke, incremental travel or battery-retained position?
Coded absolute position
A matched multi-track scale gives a unique position over a finite coded length. The iC-MU family uses a master track and a Nonius track; a longer stroke can require another architecture.
Incremental / periodic phase
Repeated poles support long scales, but a controller must establish and retain the reference. An absolute SSI value within one period is not an absolute coordinate over the entire machine stroke.
Battery-retained counting
iC-PVS buffers period counting with a backup supply. A valid datum, retained count and defined recovery after tracking or battery loss are part of the system design.
Linear magnetic encoder IC comparison
Select candidate chips to carry them into the joint enquiry. Scroll the table horizontally for scale, output and installation details. Every row links to the supporting documentation below.
| IC / add to RFQ | Position & measuring range | Resolution & accuracy | Matched magnetic scale | Outputs & speed | Air gap & magnetic environment |
|---|---|---|---|---|---|
| iC-HausSelect requirements above[S5] [S6] | Coded Nonius absolute; configurable incremental outputs 40.96 / 81.92 / 163.84 mm coded lengths; usable stroke needs end margins. Three-track/second-IC extensions require review. | 0.625 µm nominal real-time; ~0.156 µm serial with14-bit filtering. ABZ increment depends on range/FlexCount.Accuracy conditionsConverter:2 LSB of12-bit sine period with ideal inputs; installed linear accuracy must be established for target/mounting/calibration. | Master1.28 mm single poles /2.56 mm N+S period; matched Nonius16/15,32/31 or64/63;3.6 mm sensor track spacing. | SSI, BiSS-C, SPI, ABZ, STEP/DIR, Analog Sin/Cos 17 m/s per current B1, hardwareX1+; filter/output configuration limits still apply. | Target/field dependent; verify matched scale and package stack.400 µm sensor depth is not air gap.Field & stray-field limits15–100 kA/m target field at die; operating field is not stray-field immunity. Differential sensing; no guaranteed external-field immunity limit in mT supplied. |
| iC-HausSelect requirements above[S5] [S7] | Coded Nonius absolute; configurable incremental outputs 48 /96 /192 mm coded lengths; usable stroke needs end margins. Three-track/second-IC extensions require review. | ~0.732 µm nominal real-time; ~0.183 µm serial with14-bit filtering. ABZ32-period example:0.3662 µm at262144 edges.Accuracy conditionsConverter:2 LSB of12-bit sine period with ideal inputs; installed linear accuracy must be established for target/mounting/calibration. | Master1.50 mm single poles /3.00 mm N+S period; matched Nonius16/15,32/31 or64/63;3.6 mm sensor track spacing. | SSI, BiSS-C, SPI, ABZ, STEP/DIR, Analog Sin/Cos 20 m/s; filter/output configuration limits apply. | Target/field dependent; verify matched scale and package stack.400 µm sensor depth is not air gap.Field & stray-field limits15–100 kA/m target field at die; operating field is not stray-field immunity. Differential sensing; no guaranteed external-field immunity limit in mT supplied. |
| iC-HausSelect requirements above[S5] [S8] | Coded Nonius absolute; configurable incremental outputs 64 /128 /256 mm coded lengths; usable stroke needs end margins. Three-track/second-IC extensions require review. | ~0.977 µm nominal real-time; ~0.244 µm serial with14-bit filtering. ABZ32-period example:0.4883 µm at262144 edges.Accuracy conditionsConverter:2 LSB of12-bit sine period with ideal inputs; installed linear accuracy must be established for target/mounting/calibration. | Master2.00 mm single poles /4.00 mm N+S period; matched Nonius16/15,32/31 or64/63;4.0 mm sensor track spacing. | SSI, BiSS-C, SPI, ABZ, STEP/DIR, Analog Sin/Cos 20 m/s; filter/output configuration limits apply. | Target/field dependent; verify matched scale and package stack.400 µm sensor depth is not air gap.Field & stray-field limits15–100 kA/m target field at die; operating field is not stray-field immunity. Differential sensing; no guaranteed external-field immunity limit in mT supplied. |
| iC-HausSelect requirements above[S9] | Battery-retained period counter; initial datum required System/scale dependent; up to56-bit battery-buffered period counter. Initial datum and valid continuous tracking/backup required; not a unique full-stroke coded scale. | Native6-bit /64 increments per magnetic period: calculated31.25–78.125 µm for1–2.5 mm poles; finer resolution needs external interpolation.Accuracy conditionsNo numeric installed linear accuracy in preliminary factsheet; downstream interpolation, scale and mounting require validation. | Periodic scale with1.0–2.5 mm single poles; differential Hall scanning; maintain tracking and backup for retained absolute position. | SSI, BiSS-C, SPI, ABZ, Analog Sin/Cos, Parallel Up to75 m/s specifically at1.5 mm poles;25 kHz max magnetic input; other pitches/output settings need review. | Not specified in factsheet; matched scale/field/gap validation required.Field & stray-field limits10–100 kA/m target field. Battery-buffered counting requires valid backup and tracking. Differential scanning, qualitative high immunity; no quantified guaranteed mT limit in factsheet. |
| ams / ams OSRAMSelect requirements above[S1] | Period-local absolute phase + incremental active scale length minus 2 mm Hall array; extended position needs counts/reference. Absolute phase repeats every 2 mm. | 0.488 µm SSI/PWM phase; 1.953 µm per A/B transition.Accuracy conditionsINL ±5.6 µm ideal magnet at25°C, best-line fit; ±10 µm at−30…+70°C; not installed system accuracy | 1 mm single-pole width / 2 mm full N+S period; periodic index is not a unique full-scale reference. | SSI, PWM, ABZ Up to 0.65 m/s for incremental tracking; serial/PWM dynamics need separate review. | 0.3 mm typical package-to-magnet table; application typical0.3–0.6 mm, field/AGC dependentField & stray-field limits10–40 mT target-field amplitude at the specified sensor datum. Constant magnetic offset ±5 mT; constant offset only; variation including offset gradient ±2%. |
| ams / ams OSRAMSelect requirements above[S2] [S3] | Incremental quadrature; reference-dependent scale length and controller counts; requires reference/homing, no globally absolute stroke stated Lifecycle: confirm exact ordering suffix; official discontinuation notice covers AS5304A and AS5306A/B. | 25 µm per quadrature transition (160 transitions per magnetic period).Accuracy conditionstable INL2.5 LSB ideal input, (ErrMax−ErrMin)/2; calculated62.5 µm; later ideal-magnet prose says <1 LSB, inconsistency retained | 2 mm single-pole width / 4 mm full N+S period; periodic index is not a unique full-scale reference. | ABZ Up to 20 m/s, configuration dependent. | ≤0.8 mm magnet-to-package surface recommendation, magnet strength dependent; die-surface equivalent≤1.0 mmField & stray-field limits10–60 mT target-field amplitude at the specified sensor datum. Constant magnetic offset ±0.5 mT; table magnetic offset value, not a universal stray-gradient immunity rating. |
| ams / ams OSRAMSelect requirements above[S2] [S3] | Incremental quadrature; reference-dependent scale length and controller counts; requires reference/homing, no globally absolute stroke stated Lifecycle: confirm exact ordering suffix; official discontinuation notice covers AS5304A and AS5306A/B. | 15 µm per quadrature transition (160 transitions per magnetic period).Accuracy conditionstable INL2.5 LSB ideal input, (ErrMax−ErrMin)/2; calculated37.5 µm; later ideal-magnet prose says <1 LSB, inconsistency retained | 1.2 mm single-pole width / 2.4 mm full N+S period; periodic index is not a unique full-scale reference. | ABZ Up to 12 m/s, configuration dependent. | ≤0.4 mm magnet-to-package surface recommendation, magnet strength dependent; die-surface equivalent≤0.6 mmField & stray-field limits10–60 mT target-field amplitude at the specified sensor datum. Constant magnetic offset ±0.5 mT; table magnetic offset value, not a universal stray-gradient immunity rating. |
| iC-HausSelect requirements above[S10] | Incremental / period-local phase Scale length, end margins, referencing and controller counting determine usable travel; no intrinsic long-stroke limit is specified. | 0.488 µm nominal output step; 4096 steps per 2 mm magnetic period.Accuracy conditionsConverter phase accuracy ±0.35° at Vpp=4 V, adjusted; installed linear accuracy not specified | Repetitive N/S linear scale, 1.00 mm single-pole width; unique reference/counter required for longer travel Full N+S period 2 mm. | ABZ, BiSS-C, SSI, UVW Up to 4 m/s. 4096 steps per period, minimum transition distance125ns; 2kHz magnetic frequency | No universal air-gap range specified; validate field/signal amplitude for matched scaleField & stray-field limits20–100 kA/m at chip surface No quantified immunity guarantee found |
| iC-HausSelect requirements above[S11] | Incremental / period-local phase Scale length, end margins, referencing and controller counting determine usable travel; no intrinsic long-stroke limit is specified. | 0.977 µm nominal output step; 4096 steps per 4 mm magnetic period.Accuracy conditionsConverter phase accuracy ±0.35° at Vpp=4 V, adjusted; installed linear accuracy not specified | Repetitive N/S linear scale, 2.00 mm single-pole width; unique reference/counter required for longer travel Full N+S period 4 mm. | ABZ, BiSS-C, SSI, UVW Up to 8 m/s. 4096 steps per period, minimum transition distance125ns; 2kHz magnetic frequency | No universal air-gap range specified; 0.4 mm die depth is package geometry, not air gapField & stray-field limits20–100 kA/m at chip surface No quantified immunity guarantee; stray fields are a system influence |
| iC-HausSelect requirements above[S12] | Incremental / period-local phase Scale length, end margins, referencing and controller counting determine usable travel; no intrinsic long-stroke limit is specified. | 20.000 µm nominal output step; 8-bit over 5.12 mm full period.Accuracy conditionsInstalled linear accuracy not specified; relative edge error ±20% is a separate datasheet quantity | Nominal 2.56 mm single-pole width; smaller pitch via skewed mounting requires validation Full N+S period 5.12 mm. | ABZ, Analog Sin/Cos, Counter pulses Up to 5 m/s. | No universal gap specifiedField & stray-field limits20–100 kA/m at chip surface Differential homogeneous-field rejection; no quantified mT limit |
| iC-HausSelect requirements above[S13] | Analog incremental front end; external interpolation required Scale length, end margins, referencing and controller counting determine usable travel; no intrinsic long-stroke limit is specified. | External interpolator determines digital stepAccuracy conditions±1° electrical phase without offset voltage, sensor bottom-edge gap0.5mm; not installed system accuracy | 2 mm single-pole width, 4 mm N+S period; AMR outputs one electrical cycle per pole width AMR electrical period 2 mm; distinguish it from the N+S period. | Analog Sin/Cos Analog chain/interpolator dependent; no max linear speed specified | Amplitude variation ±5% characterized at0–1.5mm; accuracy characterized at0.5mm. Not a universal allowed-gap ratingField & stray-field limits|Hext| >25 kA/m at sensor bottom edge Qualitative homogeneous-field immunity; no numerical stray-field rating |
| iC-HausSelect requirements above[S14] | Analog incremental front end; external interpolation required Scale length, end margins, referencing and controller counting determine usable travel; no intrinsic long-stroke limit is specified. | External interpolator determines digital stepAccuracy conditions±1° electrical phase without offset voltage, sensor bottom-edge gap1mm; not installed system accuracy | 5 mm single-pole width, 10 mm N+S period; AMR outputs one electrical cycle per pole width AMR electrical period 5 mm; distinguish it from the N+S period. | Analog Sin/Cos Analog chain/interpolator dependent; no max linear speed specified | Amplitude variation ±5% characterized at0–2.5mm; accuracy characterized at1mm. Not a universal allowed-gap ratingField & stray-field limits|Hext| >25 kA/m at sensor bottom edge Qualitative homogeneous-field immunity; no numerical stray-field rating |
| MultiDimension Technology / MDTSelect requirements above[S15] [S16] | Analog incremental front end; external interpolation required Scale length, end margins, referencing and controller counting determine usable travel; no intrinsic long-stroke limit is specified. | External interpolator determines digital stepAccuracy conditionsGuaranteed installed positional accuracy not specified Manufacturer announcement gives typical ±1 µm repeatability, with incomplete test conditions; it is not an accuracy guarantee. | 0.4 mm single-pole width; manufacturer MLT1080/MLT2080 accessories have customizable lengths Full N+S period 0.8 mm. | Analog Sin/Cos No numeric linear-speed limit established here. | 0.15 mm test gap for output amplitude at1V,25°C; permissible gap range not specifiedField & stray-field limitsAmplitude-vs-field characteristic only; no validated universal range entered Manufacturer describes differential gradiometric rejection; no numerical mT rating |
| ams / ams OSRAMSelect requirements above[S4] [S3] | Legacy two-pole-magnet displacement sensor Historical short-stroke concept, not a periodic magnetic tape reader. Current numerical travel not verified for selection. | Current verified output increment unavailable; note’s blanket 14-bit / ±25 mm claim is not used.Accuracy conditionsNot verified for a current supplied configuration. | Historical two-pole magnet target; not a standard multipole linear scale. | SPI, PWM Not verified for current selection. | The note’s approximately 10 mm gap was not verified.Field & stray-field limitsTarget field and installation need document review. No current quantified immunity verified. |
AS5410 is a historical, discontinued reference. Confirm exact AS5304 / AS5306 ordering variants before a new design. Analog front ends require external interpolation; manufacturer converter tests and typical repeatability are not full-scale accuracy guarantees.
Match pole width, track code and air gap before choosing a scale
Same length does not mean the same magnetic code
The sensor-array spacing sets the required magnetic pole geometry. A 1.28 mm master single pole corresponds to a 2.56 mm N+S period for iC-MU128. The Nonius track uses a different matched pole spacing; copying the master pattern onto both tracks cannot reproduce that code.
AMR sensors such as iC-SM2L and iC-SM5L have an electrical cycle per single-pole width. Specify whether a drawing means a single pole, an N+S pair or an electrical cycle.
Validate the installation as a system
Define the gap datum, tolerance, tilt and lateral offset. Then verify signal amplitude, interpolation error, scale pitch error, temperature drift and stray-field gradients. A target operating field specification does not establish immunity to external motor fields.

OTV supplies encoder ICs, custom magnetic scales and complete modules
Encoder IC supply
Request chips in the quantity your project needs, including small sample batches, subject to availability. We also support PCBA prototyping using your Gerber files, BOM and assembly information.
Explore encoder IC supply →Matched magnetic scales
Discuss pole width, single or multi-track coding, usable stroke, end margins, backing, adhesive, width and thickness together with the selected sensor and installation gap.
Explore magnetic scales and encoder tape →Complete encoder modules
Prefer a readhead and scale assembly? Review existing absolute and incremental linear modules, or discuss a custom assembly. Module ratings apply to that matched product configuration.
Absolute linear encoder modules →Incremental linear encoder modules →
For rotary projects, use the off-axis rotary encoder IC selector and matched magnetic rings and encoder disks.
Request a joint quotation: encoder IC + custom magnetic scale
Choose chips in the table, or leave the choice to OTV. Add the mechanical constraints below; your filter settings and selected chips are included automatically in the enquiry form.
Review the generated requirements before sending. A shortlist is a design starting point, not a compatibility or supply guarantee.
Engineering questions before a linear encoder design is frozen
Can SSI or BiSS alone prove that a chip is full-stroke absolute?
No. AS5311 and MHL devices report phase within a repeating magnetic period. A full machine coordinate also needs a unique coded scale or a valid count and reference architecture. The interface name does not define the measuring range.
Does a smaller output step guarantee better positioning accuracy?
No. Quantization, signal interpolation, magnetic pitch error and mounting error are different contributions. Compare specifications under their stated conditions, then verify the matched scale and readhead across the usable stroke.
Can an incremental scale have any travel length?
The repeated pattern is not limited to a single magnetic period, but scale manufacturing length, mechanical mounting, controller counting capacity, speed and reference recovery still constrain the usable system.
Can I request samples without a final chip selection?
Yes. Send the required stroke, resolution, output interface and mounting envelope. OTV can review IC and scale candidates together; confirm availability and a validation plan before design release.
Datasheet sources and specification conditions
Reviewed 25 November 2026. Numerical output steps calculated from documented period and interpolation are identified above. Unpublished installation limits remain unverified rather than assumed.
- [S1] AS5311 datasheet, Rev 1.13. pp. 7–8, 12, 19–20: period-local SSI/PWM, AB step, ideal-magnet INL and field conditions.
- [S2] AS5304 / AS5306 datasheet, v3-00. pp. 7, 9–11, 13, 15–16, 22. INL uses the conservative 2.5 LSB electrical-table value; prose elsewhere differs.
- [S3] ams official product discontinuation notice, 10 Aug 2021. AS5410-ZTSM, AS5304A and AS5306A/B ordering variants. Availability must be confirmed.
- [S4] AS5410 preliminary Rev 1.5, historical manufacturer-authored PDF. Distributor-hosted historical reference, not a current production recommendation; stroke depends on the specific two-pole magnet.
- [S5] iC-MU128 / current iC-MU Series B1 documentation. B1 (2025), hardware X1+: p. 11 speed, p. 49 serial filtered increments. Nominal real-time steps are calculated as N+S period / 4096.
- [S6] iC-Haus MU family linear-range factsheet, Rev 6. Basic two-track coded lengths and advanced three-track / second-IC extensions are different architectures.
- [S7] iC-MU150 documentation. Local E1: pp. 10–11, 15, 41–42, 50; scale geometry and serial interpolation conditions.
- [S8] iC-MU200 documentation. Local B2: pp. 8–9, 14, 40–41, 48; scale geometry and serial interpolation conditions.
- [S9] iC-PVS preliminary factsheet, Rev 2. pp. 1–2: battery-buffered counting and native 6-bit phase. Step = N+S period / 64.
- [S10] iC-MHL100 datasheet, A1 preliminary. pp. 1–2, 7–9, 22, 26: converter, speed and BiSS framing. UVW commutation is not the full-resolution position output.
- [S11] iC-MHL200 datasheet, E1. pp. 1–2, 7–9, 22, 26: 4 mm magnetic period, converter accuracy and serial output.
- [S12] iC-ML datasheet, A3. pp. 1–2, 4–5, 7: 2.56 mm pole width, 8-bit interpolation and output options.
- [S13] iC-SM2L datasheet, C1. pp. 1–2, 5: AMR electrical period, specified phase-error test gap and amplitude-characterization range.
- [S14] iC-SM5L datasheet, B2. pp. 1–2, 5: AMR electrical period and gap-dependent amplitude; external interpolation required.
- [S15] TMR4101 datasheet: local CN v1.2.4 / online EN v1.2.3. Analog output, 0.4 mm single poles. 0.15 mm is an amplitude-test gap, not a guaranteed installation range.
- [S16] MultiDimension Technology TMR4101 manufacturer announcement. Typical ±1 µm repeatability is not a guaranteed installed accuracy specification.